Skip to content

PLCamera.CounterResetSourceEnum Class#

Sets which source signal will reset the currently selected counter.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Visibility: Beginner

Selected by: CounterSelector

The feature documentation may provide more information.

Inheritance Hierarchy#

System.Object
  Basler.Pylon.ParameterListEnum
    Basler.Pylon.PLCamera.CounterResetSourceEnum

Constructors#

 NameDescription
Public methodPLCamera.CounterResetSourceEnum Initializes a new instance of the PLCamera.CounterResetSourceEnum class
 

Properties#

 NameDescription
Public propertyAcquisitionActive

The selected counter can be reset by an Acquisition Active signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyAction1

The selected counter can be reset by an action command that is defined by action signal 1.

Applies to: ace 2 GigE, dart GigE, racer 2S 5GigE and racer 2S GigE

Public propertyAction2

The selected counter can be reset by an action command that is defined by action signal 2.

Applies to: ace 2 GigE

Public propertyCC1

The selected counter can be reset by a CC1 signal.

Applies to: CameraLink and ace GigE

Public propertyCC2

The selected counter can be reset by a CC2 signal.

Applies to: CameraLink and ace GigE

Public propertyCC3

The selected counter can be reset by a CC3 signal.

Applies to: CameraLink and ace GigE

Public propertyCC4

The selected counter can be reset by a CC4 signal.

Applies to: CameraLink and ace GigE

Public propertyCounter1Active

The selected counter can be reset by a Counter 1 Active signal. By default, a Counter 1 Active signal is generated whenever counter 1 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter1End

The selected counter can be reset by a Counter 1 End signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter1Start

The selected counter can be reset by a Counter 1 Start signal. A Counter 1 Start signal is generated whenever counter 1 is started.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter2Active

The selected counter can be reset by a Counter 2 Active signal. By default, a Counter 2 Active signal is generated whenever counter 2 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter2End

The selected counter can be reset by a Counter 2 End signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter2Start

The selected counter can be reset by a Counter 2 Start signal. A Counter 2 Start signal is generated whenever counter 2 is started.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter3Active

The selected counter can be reset by a Counter 3 Active signal. By default, a Counter 3 Active signal is generated whenever counter 3 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter3End

The selected counter can be reset by a Counter 3 End signal.

Applies to: ace USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter3Start

The selected counter can be reset by a Counter 3 Start signal. A Counter 3 Start signal is generated whenever counter 3 is started.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter4Active

The selected counter can be reset by a Counter 4 Active signal. By default, a Counter 4 Active signal is generated whenever counter 4 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter4End

The selected counter can be reset by a Counter 4 End signal.

Applies to: ace USB, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter4Start

The selected counter can be reset by a Counter 4 Start signal. A Counter 4 Start signal is generated whenever counter 4 is started.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCxpTrigger0

The selected counter can be reset by a CXP Trigger 0 signal.

Applies to: ace 2 CXP, boost CoaXPress, racer 2 CXP and racer 2S CXP

Public propertyCxpTrigger1

The selected counter can be reset by a CXP Trigger 1 signal.

Applies to: ace 2 CXP, boost CoaXPress, racer 2 CXP and racer 2S CXP

Public propertyEncoder1

The selected counter can be reset by an Encoder 1 signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyEncoderReverse1

The selected counter can be reset by an Encoder Reverse 1 signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyExposureActive

The selected counter can be reset by an Exposure Active signal. By default, an Exposure Active signal is generated whenever exposure is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyExposureStart

The selected counter can be reset by an Exposure Start signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyExposureTriggerWait

The selected counter can be reset by an Exposure Trigger Wait signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyFlashWindow

The selected counter can be reset by a Flash Window signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE and dart USB

Public propertyFrameActive

The selected counter can be reset by a Frame Active signal.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyFrameBurstActive

The selected counter can be reset by a Frame Burst Active signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE and racer 2S GigE

Public propertyFrameBurstTriggerWait

The selected counter can be reset by a Frame Burst Trigger Wait signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE and racer 2S GigE

Public propertyFrameTriggerWait

The selected counter can be reset by a Frame Trigger Wait signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyFrequencyConverter

The selected counter can be reset by a Frequency Converter signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyLine1

The selected counter can be reset by a signal applied to Line 1.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyLine2

The selected counter can be reset by a signal applied to Line 2.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, ace USB, boost CoaXPress, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyLine3

The selected counter can be reset by a signal applied to Line 3.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyLine4

The selected counter can be reset by a signal applied to Line 4.

Applies to: CameraLink, ace GigE, ace USB and dart USB

Public propertyLine5

The selected counter can be reset by a signal applied to Line 5.

Applies to: CameraLink and ace GigE

Public propertyLine6

The selected counter can be reset by a signal applied to Line 6.

Applies to: CameraLink and ace GigE

Public propertyLine7

The selected counter can be reset by a signal applied to Line 7.

Applies to: CameraLink and ace GigE

Public propertyLine8

The selected counter can be reset by a signal applied to Line 8.

Applies to: CameraLink and ace GigE

Public propertyLineTriggerWait

The selected counter can be reset by a Line Trigger Wait signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyName The full name of CounterResetSource (Overrides ParameterListEnum.Name.)
Public propertyOff

The counter reset is disabled.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyPeriodicSignal1

The selected counter can be reset by a Periodic Signal 1 signal.

Applies to: ace 2 GigE, dart GigE, racer 2S 5GigE and racer 2S GigE

Public propertySoftware

The selected counter can be reset by a software command.

Applies to: CameraLink, ace GigE and ace USB

Public propertySoftwareSignal1

The selected counter can be reset by a Software Signal 1 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertySoftwareSignal2

The selected counter can be reset by a Software Signal 2 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertySoftwareSignal3

The selected counter can be reset by a Software Signal 3 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyTimer1Active

The selected counter can be reset by a Timer 1 Active signal. By default, a Timer 1 Active signal is generated whenever timer 1 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyTimer1End

The selected counter can be reset by a Timer 1 End signal. A Timer 1 End signal is generated whenever timer 1 has elapsed.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyTimer2Active

The selected counter can be reset by a Timer 2 Active signal. By default, a Timer 2 Active signal is generated whenever timer 2 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyTimer2End

The selected counter can be reset by a Timer 2 End signal. A Timer 2 End signal is generated whenever timer 2 has elapsed.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyVInput1

This enumeration value selects VInput1 as the source for counter reset.

Applies to: CameraLink and ace GigE

Public propertyVInput2

This enumeration value selects VInput2 as the source for counter reset.

Applies to: CameraLink and ace GigE

Public propertyVInput3

This enumeration value selects VInput3 as the source for counter reset.

Applies to: CameraLink and ace GigE

Public propertyVInput4

This enumeration value selects VInput4 as the source for counter reset.

Applies to: CameraLink and ace GigE

Public propertyVInputDecActive

This enumeration value selects Virtual Input Decoder Active as the source for counter reset.

Applies to: CameraLink and ace GigE

 

Methods#

 NameDescription
Public methodToString The full name of CounterResetSource (Overrides Object.ToString()()()().)
 

PLCamera.CounterResetSourceEnum.ToString Method#

The full name of CounterResetSource

Return Value#

Type: String
Returns the full name of CounterResetSource

PLCamera.CounterResetSourceEnum Constructor#

Initializes a new instance of the PLCamera.CounterResetSourceEnum class

PLCamera.CounterResetSourceEnum.AcquisitionActive Property#

The selected counter can be reset by an Acquisition Active signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Action1 Property#

The selected counter can be reset by an action command that is defined by action signal 1.

Applies to: ace 2 GigE, dart GigE, racer 2S 5GigE and racer 2S GigE

PLCamera.CounterResetSourceEnum.Action2 Property#

The selected counter can be reset by an action command that is defined by action signal 2.

Applies to: ace 2 GigE

PLCamera.CounterResetSourceEnum.CC1 Property#

The selected counter can be reset by a CC1 signal.

Applies to: CameraLink and ace GigE

PLCamera.CounterResetSourceEnum.CC2 Property#

The selected counter can be reset by a CC2 signal.

Applies to: CameraLink and ace GigE

PLCamera.CounterResetSourceEnum.CC3 Property#

The selected counter can be reset by a CC3 signal.

Applies to: CameraLink and ace GigE

PLCamera.CounterResetSourceEnum.CC4 Property#

The selected counter can be reset by a CC4 signal.

Applies to: CameraLink and ace GigE

PLCamera.CounterResetSourceEnum.Counter1Active Property#

The selected counter can be reset by a Counter 1 Active signal. By default, a Counter 1 Active signal is generated whenever counter 1 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Counter1End Property#

The selected counter can be reset by a Counter 1 End signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Counter1Start Property#

The selected counter can be reset by a Counter 1 Start signal. A Counter 1 Start signal is generated whenever counter 1 is started.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Counter2Active Property#

The selected counter can be reset by a Counter 2 Active signal. By default, a Counter 2 Active signal is generated whenever counter 2 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Counter2End Property#

The selected counter can be reset by a Counter 2 End signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Counter2Start Property#

The selected counter can be reset by a Counter 2 Start signal. A Counter 2 Start signal is generated whenever counter 2 is started.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Counter3Active Property#

The selected counter can be reset by a Counter 3 Active signal. By default, a Counter 3 Active signal is generated whenever counter 3 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Counter3End Property#

The selected counter can be reset by a Counter 3 End signal.

Applies to: ace USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Counter3Start Property#

The selected counter can be reset by a Counter 3 Start signal. A Counter 3 Start signal is generated whenever counter 3 is started.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Counter4Active Property#

The selected counter can be reset by a Counter 4 Active signal. By default, a Counter 4 Active signal is generated whenever counter 4 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Counter4End Property#

The selected counter can be reset by a Counter 4 End signal.

Applies to: ace USB, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Counter4Start Property#

The selected counter can be reset by a Counter 4 Start signal. A Counter 4 Start signal is generated whenever counter 4 is started.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.CxpTrigger0 Property#

The selected counter can be reset by a CXP Trigger 0 signal.

Applies to: ace 2 CXP, boost CoaXPress, racer 2 CXP and racer 2S CXP

PLCamera.CounterResetSourceEnum.CxpTrigger1 Property#

The selected counter can be reset by a CXP Trigger 1 signal.

Applies to: ace 2 CXP, boost CoaXPress, racer 2 CXP and racer 2S CXP

PLCamera.CounterResetSourceEnum.Encoder1 Property#

The selected counter can be reset by an Encoder 1 signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.EncoderReverse1 Property#

The selected counter can be reset by an Encoder Reverse 1 signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.ExposureActive Property#

The selected counter can be reset by an Exposure Active signal. By default, an Exposure Active signal is generated whenever exposure is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.ExposureStart Property#

The selected counter can be reset by an Exposure Start signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.ExposureTriggerWait Property#

The selected counter can be reset by an Exposure Trigger Wait signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.FlashWindow Property#

The selected counter can be reset by a Flash Window signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE and dart USB

PLCamera.CounterResetSourceEnum.FrameActive Property#

The selected counter can be reset by a Frame Active signal.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.FrameBurstActive Property#

The selected counter can be reset by a Frame Burst Active signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE and racer 2S GigE

PLCamera.CounterResetSourceEnum.FrameBurstTriggerWait Property#

The selected counter can be reset by a Frame Burst Trigger Wait signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE and racer 2S GigE

PLCamera.CounterResetSourceEnum.FrameTriggerWait Property#

The selected counter can be reset by a Frame Trigger Wait signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.FrequencyConverter Property#

The selected counter can be reset by a Frequency Converter signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Line1 Property#

The selected counter can be reset by a signal applied to Line 1.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Line2 Property#

The selected counter can be reset by a signal applied to Line 2.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, ace USB, boost CoaXPress, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Line3 Property#

The selected counter can be reset by a signal applied to Line 3.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Line4 Property#

The selected counter can be reset by a signal applied to Line 4.

Applies to: CameraLink, ace GigE, ace USB and dart USB

PLCamera.CounterResetSourceEnum.Line5 Property#

The selected counter can be reset by a signal applied to Line 5.

Applies to: CameraLink and ace GigE

PLCamera.CounterResetSourceEnum.Line6 Property#

The selected counter can be reset by a signal applied to Line 6.

Applies to: CameraLink and ace GigE

PLCamera.CounterResetSourceEnum.Line7 Property#

The selected counter can be reset by a signal applied to Line 7.

Applies to: CameraLink and ace GigE

PLCamera.CounterResetSourceEnum.Line8 Property#

The selected counter can be reset by a signal applied to Line 8.

Applies to: CameraLink and ace GigE

PLCamera.CounterResetSourceEnum.LineTriggerWait Property#

The selected counter can be reset by a Line Trigger Wait signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Name Property#

The full name of CounterResetSource

PLCamera.CounterResetSourceEnum.Off Property#

The counter reset is disabled.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.PeriodicSignal1 Property#

The selected counter can be reset by a Periodic Signal 1 signal.

Applies to: ace 2 GigE, dart GigE, racer 2S 5GigE and racer 2S GigE

PLCamera.CounterResetSourceEnum.Software Property#

The selected counter can be reset by a software command.

Applies to: CameraLink, ace GigE and ace USB

PLCamera.CounterResetSourceEnum.SoftwareSignal1 Property#

The selected counter can be reset by a Software Signal 1 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.SoftwareSignal2 Property#

The selected counter can be reset by a Software Signal 2 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.SoftwareSignal3 Property#

The selected counter can be reset by a Software Signal 3 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Timer1Active Property#

The selected counter can be reset by a Timer 1 Active signal. By default, a Timer 1 Active signal is generated whenever timer 1 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Timer1End Property#

The selected counter can be reset by a Timer 1 End signal. A Timer 1 End signal is generated whenever timer 1 has elapsed.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Timer2Active Property#

The selected counter can be reset by a Timer 2 Active signal. By default, a Timer 2 Active signal is generated whenever timer 2 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.Timer2End Property#

The selected counter can be reset by a Timer 2 End signal. A Timer 2 End signal is generated whenever timer 2 has elapsed.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.CounterResetSourceEnum.VInput1 Property#

This enumeration value selects VInput1 as the source for counter reset.

Applies to: CameraLink and ace GigE

PLCamera.CounterResetSourceEnum.VInput2 Property#

This enumeration value selects VInput2 as the source for counter reset.

Applies to: CameraLink and ace GigE

PLCamera.CounterResetSourceEnum.VInput3 Property#

This enumeration value selects VInput3 as the source for counter reset.

Applies to: CameraLink and ace GigE

PLCamera.CounterResetSourceEnum.VInput4 Property#

This enumeration value selects VInput4 as the source for counter reset.

Applies to: CameraLink and ace GigE

PLCamera.CounterResetSourceEnum.VInputDecActive Property#

This enumeration value selects Virtual Input Decoder Active as the source for counter reset.

Applies to: CameraLink and ace GigE