Basler Vision Connector Messaging: Retrieving Available User Sets#

The GenICam protocol allows you to store parameter sets on the camera. With the Basler Vision Connector you can save, load, and define the default user set to be used on camera restart.

With the following message, you can retrieve the available user sets on the camera.

JSON Payload#

Field Optional 键入 描述
TransactionID String Transaction identification
操作 String Method called. Fixed value: GetUserSets
DeviceID String Device identification
{
    "TransactionID": "1232116",
    "Action": "GetUserSets",
    "DeviceID": "12323454754"
}

Response Object#

Field Optional 键入 描述
TransactionID String Transaction identification
ReturnCode Integer (32-bit unsigned) Message code following Message Codes
消息 String Response message
UserSetList User Set Object Array Object containing the available parameter settings

User Set Object#

Field Optional 键入 描述
DisplayName String Represents the name of the user set.
String Parameter value that needs to be used to set the user set value.
IntValue Integer (64-bit signed) Integer value of the user set
描述 String User set description
{
    "TransactionID": "12323454754",
    "ReturnCode": 0,
    "Message": "Userset retrieved.",
    "UserSetList": [
      {
        "DisplayName": "Default User Set",
        "Value": "Default",
        "IntValue": 0,
        "Description": "The default factory set can be loaded."
      },
      {
        "DisplayName": "User Set 1",
        "Value": "UserSet1",
        "IntValue": 1,
        "Description": "User set 1 can be saved, loaded, or configured."
      },
      {
        "DisplayName": "User Set 2",
        "Value": "UserSet2",
        "IntValue": 2,
        "Description": "User set 2 can be saved, loaded, or configured."
      },
      {
        "DisplayName": "User Set 3",
        "Value": "UserSet3",
        "IntValue": 3,
        "Description": "User set 3 can be saved, loaded, or configured."
      }
    ]
}