Name | Description | |
---|---|---|
![]() | PLTransportLayer.TriggerOutSelectGPO5Enum | Initializes a new instance of the PLTransportLayer.TriggerOutSelectGPO5Enum class |
Properties#
Name | Description | |
---|---|---|
![]() | BypassFrontGPI0 | Bypass the Front GPI 0 signal directly to the output Applies to: CoaXPress |
![]() | BypassFrontGPI1 | Bypass the Front GPI 1 signal directly to the output Applies to: CoaXPress |
![]() | BypassFrontGPI2 | Bypass the Front GPI 2 signal directly to the output Applies to: CoaXPress |
![]() | BypassFrontGPI3 | Bypass the Front GPI 3 signal directly to the output Applies to: CoaXPress |
![]() | BypassGPI0 | Bypass the GPI 0 signal directly to the output Applies to: CoaXPress |
![]() | BypassGPI1 | Bypass the GPI 1 signal directly to the output Applies to: CoaXPress |
![]() | BypassGPI2 | Bypass the GPI 2 signal directly to the output Applies to: CoaXPress |
![]() | BypassGPI3 | Bypass the GPI 3 signal directly to the output Applies to: CoaXPress |
![]() | BypassGPI4 | Bypass the GPI 4 signal directly to the output Applies to: CoaXPress |
![]() | BypassGPI5 | Bypass the GPI 5 signal directly to the output Applies to: CoaXPress |
![]() | BypassGPI6 | Bypass the GPI 6 signal directly to the output Applies to: CoaXPress |
![]() | BypassGPI7 | Bypass the GPI 7 signal directly to the output Applies to: CoaXPress |
![]() | CamAPulseGenerator0 | Camera port A Pulse Generator 0 Applies to: CoaXPress |
![]() | CamAPulseGenerator1 | Camera port A Pulse Generator 1 Applies to: CoaXPress |
![]() | CamAPulseGenerator2 | Camera port A Pulse Generator 2 Applies to: CoaXPress |
![]() | CamAPulseGenerator3 | Camera port A Pulse Generator 3 Applies to: CoaXPress |
![]() | CamBPulseGenerator0 | The output source is set to Cam B Pulse Generator 0. Applies to: CoaXPress |
![]() | CamBPulseGenerator1 | The output source is set to Cam B Pulse Generator 1. Applies to: CoaXPress |
![]() | CamBPulseGenerator2 | The output source is set to Cam B Pulse Generator 2. Applies to: CoaXPress |
![]() | CamBPulseGenerator3 | The output source is set to Cam B Pulse Generator 3. Applies to: CoaXPress |
![]() | CamCPulseGenerator0 | The output source is set to Cam C Pulse Generator 0. Applies to: CoaXPress |
![]() | CamCPulseGenerator1 | The output source is set to Cam C Pulse Generator 1. Applies to: CoaXPress |
![]() | CamCPulseGenerator2 | The output source is set to Cam C Pulse Generator 2. Applies to: CoaXPress |
![]() | CamCPulseGenerator3 | The output source is set to Cam C Pulse Generator 3. Applies to: CoaXPress |
![]() | CamDPulseGenerator0 | The output source is set to Cam D Pulse Generator 0. Applies to: CoaXPress |
![]() | CamDPulseGenerator1 | The output source is set to Cam D Pulse Generator 1. Applies to: CoaXPress |
![]() | CamDPulseGenerator2 | The output source is set to Cam D Pulse Generator 2. Applies to: CoaXPress |
![]() | CamDPulseGenerator3 | The output source is set to Cam D Pulse Generator 3. Applies to: CoaXPress |
![]() | GND | A static zero Applies to: CoaXPress |
![]() | Name | The full name of TriggerOutSelectGPO5 (Overrides ParameterListEnum.Name.) |
![]() | NotBypassFrontGPI0 | The output source is set to Not Bypass Front-GPI 0. Applies to: CoaXPress |
![]() | NotBypassFrontGPI1 | The output source is set to Not Bypass Front-GPI 1. Applies to: CoaXPress |
![]() | NotBypassFrontGPI2 | The output source is set to Not Bypass Front-GPI 2. Applies to: CoaXPress |
![]() | NotBypassFrontGPI3 | The output source is set to Not Bypass Front-GPI 3. Applies to: CoaXPress |
![]() | NotBypassGPI0 | Bypass the inverted GPI 0 signal directly to the output Applies to: CoaXPress |
![]() | NotBypassGPI1 | Bypass the inverted GPI 1 signal directly to the output Applies to: CoaXPress |
![]() | NotBypassGPI2 | Bypass the inverted GPI 2 signal directly to the output Applies to: CoaXPress |
![]() | NotBypassGPI3 | Bypass the inverted GPI 3 signal directly to the output Applies to: CoaXPress |
![]() | NotBypassGPI4 | Bypass the inverted GPI 4 signal directly to the output Applies to: CoaXPress |
![]() | NotBypassGPI5 | Bypass the inverted GPI 5 signal directly to the output Applies to: CoaXPress |
![]() | NotBypassGPI6 | Bypass the inverted GPI 6 signal directly to the output Applies to: CoaXPress |
![]() | NotBypassGPI7 | Bypass the inverted GPI 7 signal directly to the output Applies to: CoaXPress |
![]() | NotCamAPulseGenerator0 | Inverted signal of camera port A Pulse Generator 0 Applies to: CoaXPress |
![]() | NotCamAPulseGenerator1 | Inverted signal of camera port A Pulse Generator 1 Applies to: CoaXPress |
![]() | NotCamAPulseGenerator2 | Inverted signal of camera port A Pulse Generator 2 Applies to: CoaXPress |
![]() | NotCamAPulseGenerator3 | Inverted signal of camera port A Pulse Generator 3 Applies to: CoaXPress |
![]() | NotCamBPulseGenerator0 | The output source is set to Not Cam B Pulse Generator 0. Applies to: CoaXPress |
![]() | NotCamBPulseGenerator1 | The output source is set to Not Cam B Pulse Generator 1. Applies to: CoaXPress |
![]() | NotCamBPulseGenerator2 | The output source is set to Not Cam B Pulse Generator 2. Applies to: CoaXPress |
![]() | NotCamBPulseGenerator3 | The output source is set to Not Cam B Pulse Generator 3. Applies to: CoaXPress |
![]() | NotCamCPulseGenerator0 | The output source is set to Not Cam C Pulse Generator 0. Applies to: CoaXPress |
![]() | NotCamCPulseGenerator1 | The output source is set to Not Cam C Pulse Generator 1. Applies to: CoaXPress |
![]() | NotCamCPulseGenerator2 | The output source is set to Not Cam C Pulse Generator 2. Applies to: CoaXPress |
![]() | NotCamCPulseGenerator3 | The output source is set to Not Cam C Pulse Generator 3. Applies to: CoaXPress |
![]() | NotCamDPulseGenerator0 | The output source is set to Not Cam D Pulse Generator 0. Applies to: CoaXPress |
![]() | NotCamDPulseGenerator1 | The output source is set to Not Cam D Pulse Generator 1. Applies to: CoaXPress |
![]() | NotCamDPulseGenerator2 | The output source is set to Not Cam D Pulse Generator 2. Applies to: CoaXPress |
![]() | NotCamDPulseGenerator3 | The output source is set to Not Cam D Pulse Generator 3. Applies to: CoaXPress |
![]() | NotPulseGenerator0 | Inverted signal of pulse generator 0 Applies to: CoaXPress |
![]() | NotPulseGenerator1 | Inverted signal of pulse generator 1 Applies to: CoaXPress |
![]() | NotPulseGenerator2 | Inverted signal of pulse generator 2 Applies to: CoaXPress |
![]() | NotPulseGenerator3 | Inverted signal of pulse generator 3 Applies to: CoaXPress |
![]() | PulseGenerator0 | The source for the output statistics is set to Pulse Generator 0. Applies to: CoaXPress |
![]() | PulseGenerator1 | The source for the output statistics is set to Pulse Generator 1. Applies to: CoaXPress |
![]() | PulseGenerator2 | The source for the output statistics is set to Pulse Generator 2. Applies to: CoaXPress |
![]() | PulseGenerator3 | The source for the output statistics is set to Pulse Generator 3. Applies to: CoaXPress |
![]() | VCC | A static one Applies to: CoaXPress |
Methods#
Name | Description | |
---|---|---|
![]() | ToString | The full name of TriggerOutSelectGPO5 (Overrides Object.ToString()()()().) |
PLTransportLayer.TriggerOutSelectGPO5Enum.ToString Method#
The full name of TriggerOutSelectGPO5
Return Value#
Type: String
Returns the full name of TriggerOutSelectGPO5
PLTransportLayer.TriggerOutSelectGPO5Enum Constructor#
Initializes a new instance of the PLTransportLayer.TriggerOutSelectGPO5Enum class
PLTransportLayer.TriggerOutSelectGPO5Enum.BypassFrontGPI0 Property#
Bypass the Front GPI 0 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.BypassFrontGPI1 Property#
Bypass the Front GPI 1 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.BypassFrontGPI2 Property#
Bypass the Front GPI 2 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.BypassFrontGPI3 Property#
Bypass the Front GPI 3 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.BypassGPI0 Property#
Bypass the GPI 0 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.BypassGPI1 Property#
Bypass the GPI 1 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.BypassGPI2 Property#
Bypass the GPI 2 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.BypassGPI3 Property#
Bypass the GPI 3 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.BypassGPI4 Property#
Bypass the GPI 4 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.BypassGPI5 Property#
Bypass the GPI 5 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.BypassGPI6 Property#
Bypass the GPI 6 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.BypassGPI7 Property#
Bypass the GPI 7 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamAPulseGenerator0 Property#
Camera port A Pulse Generator 0
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamAPulseGenerator1 Property#
Camera port A Pulse Generator 1
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamAPulseGenerator2 Property#
Camera port A Pulse Generator 2
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamAPulseGenerator3 Property#
Camera port A Pulse Generator 3
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamBPulseGenerator0 Property#
The output source is set to Cam B Pulse Generator 0.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamBPulseGenerator1 Property#
The output source is set to Cam B Pulse Generator 1.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamBPulseGenerator2 Property#
The output source is set to Cam B Pulse Generator 2.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamBPulseGenerator3 Property#
The output source is set to Cam B Pulse Generator 3.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamCPulseGenerator0 Property#
The output source is set to Cam C Pulse Generator 0.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamCPulseGenerator1 Property#
The output source is set to Cam C Pulse Generator 1.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamCPulseGenerator2 Property#
The output source is set to Cam C Pulse Generator 2.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamCPulseGenerator3 Property#
The output source is set to Cam C Pulse Generator 3.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamDPulseGenerator0 Property#
The output source is set to Cam D Pulse Generator 0.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamDPulseGenerator1 Property#
The output source is set to Cam D Pulse Generator 1.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamDPulseGenerator2 Property#
The output source is set to Cam D Pulse Generator 2.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.CamDPulseGenerator3 Property#
The output source is set to Cam D Pulse Generator 3.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.GND Property#
A static zero
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.Name Property#
The full name of TriggerOutSelectGPO5
PLTransportLayer.TriggerOutSelectGPO5Enum.NotBypassFrontGPI0 Property#
The output source is set to Not Bypass Front-GPI 0.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotBypassFrontGPI1 Property#
The output source is set to Not Bypass Front-GPI 1.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotBypassFrontGPI2 Property#
The output source is set to Not Bypass Front-GPI 2.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotBypassFrontGPI3 Property#
The output source is set to Not Bypass Front-GPI 3.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotBypassGPI0 Property#
Bypass the inverted GPI 0 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotBypassGPI1 Property#
Bypass the inverted GPI 1 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotBypassGPI2 Property#
Bypass the inverted GPI 2 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotBypassGPI3 Property#
Bypass the inverted GPI 3 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotBypassGPI4 Property#
Bypass the inverted GPI 4 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotBypassGPI5 Property#
Bypass the inverted GPI 5 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotBypassGPI6 Property#
Bypass the inverted GPI 6 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotBypassGPI7 Property#
Bypass the inverted GPI 7 signal directly to the output
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamAPulseGenerator0 Property#
Inverted signal of camera port A Pulse Generator 0
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamAPulseGenerator1 Property#
Inverted signal of camera port A Pulse Generator 1
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamAPulseGenerator2 Property#
Inverted signal of camera port A Pulse Generator 2
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamAPulseGenerator3 Property#
Inverted signal of camera port A Pulse Generator 3
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamBPulseGenerator0 Property#
The output source is set to Not Cam B Pulse Generator 0.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamBPulseGenerator1 Property#
The output source is set to Not Cam B Pulse Generator 1.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamBPulseGenerator2 Property#
The output source is set to Not Cam B Pulse Generator 2.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamBPulseGenerator3 Property#
The output source is set to Not Cam B Pulse Generator 3.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamCPulseGenerator0 Property#
The output source is set to Not Cam C Pulse Generator 0.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamCPulseGenerator1 Property#
The output source is set to Not Cam C Pulse Generator 1.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamCPulseGenerator2 Property#
The output source is set to Not Cam C Pulse Generator 2.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamCPulseGenerator3 Property#
The output source is set to Not Cam C Pulse Generator 3.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamDPulseGenerator0 Property#
The output source is set to Not Cam D Pulse Generator 0.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamDPulseGenerator1 Property#
The output source is set to Not Cam D Pulse Generator 1.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamDPulseGenerator2 Property#
The output source is set to Not Cam D Pulse Generator 2.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotCamDPulseGenerator3 Property#
The output source is set to Not Cam D Pulse Generator 3.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotPulseGenerator0 Property#
Inverted signal of pulse generator 0
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotPulseGenerator1 Property#
Inverted signal of pulse generator 1
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotPulseGenerator2 Property#
Inverted signal of pulse generator 2
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.NotPulseGenerator3 Property#
Inverted signal of pulse generator 3
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.PulseGenerator0 Property#
The source for the output statistics is set to Pulse Generator 0.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.PulseGenerator1 Property#
The source for the output statistics is set to Pulse Generator 1.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.PulseGenerator2 Property#
The source for the output statistics is set to Pulse Generator 2.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.PulseGenerator3 Property#
The source for the output statistics is set to Pulse Generator 3.
Applies to: CoaXPress
PLTransportLayer.TriggerOutSelectGPO5Enum.VCC Property#
A static one